Part Number Hot Search : 
R29791 V470M 2N558 48D05 MBR10 TU800G NX6309GH SDA42GHF
Product Description
Full Text Search
 

To Download CSB01A001 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  sp e - 15 - 8 - 004 /c /jc page 1 of 8 specification part no: cs b.01.a.001 product name: cellular booster 850/1900 mhz 2x sma(f) connectors and dc power connector features: 15db gain cellular signal booster frequency: 824 - 894mhz, 1850 - 1990 mhz 27 dbm output power easy "plug & play" direct connect device automatic gain & o scillation control passive bypass technology sma female connectors 8.0 to 36.0 vdc input led diagnostics fcc & ic type accepted dims: 4.9" l x 2.7" w x 0.92" h rohs compliant
sp e - 15 - 8 - 004 /c /jc page 2 of 8 1. introduction the cs b.01 cellular booster is a high performance, microprocessor control led, bi - directional rf booster for the north american 850 mhz cellular and 1900 mhz pcs frequency bands. the boost er has an automatic gain and oscillation control system that will automatically adjust the gain and output power if a sig nal anomaly occurs. this boost er is designed to operate as a direct connect "plug and play" unit for maximum performance in weak signal coverage areas. the cs b.01 is equipped with passive bypass technology. this feature allows the boost er to be passively bypassed and become a pass through cable when boosting is not necessary, during loss of power or when a fault is detected. this is useful i n applications where the boost er is mobile, moving in and out o f poor signal areas. the boost er will bypass itself when close to cell towers, completely eliminating any potential for network disrupting noise power caused by too much amplification near a cell tower. the technology is also extremely useful in fire and security system installations where a network connection must always be maintained, even with loss of power. the cs b.01 has a wide input voltage range of 8.0 to 36.0v allowing for a variety of power sources. integrated led diagnostics alert the user to events such as initialization, normal op eration, increase in gain, decrease in gain, and fault detection . please see the operators manual for more i nf ormation.
sp e - 15 - 8 - 004 /c /jc page 3 of 8 2. specification electrical frequency 824 mhz - 894 mhz, 1850 mhz - 1990 mhz maximum rf output power 27 dbm maximum rf input power - 20 dbm nominal rf gain 15 db current draw @ 12v idle:250 ma, max: 1a input voltage +8.0 to 36.0v impedance 50 ohms mechanical dimensions 4.9" l x 2.7" w x 0.92" h weight ? connector sma(f) environmental operating temperature - 20c to +50c storage temperature - 30c to +70c relative humidity 5% to 90% storage
sp e - 15 - 8 - 004 /c /jc page 4 of 8 3. parts included in the kit depending upon the connector type of t he cellular device, taoglas can customize the m2m kit to include the a ppropriate adapters to ensure a seamless and quick inst allation. adapter types include, but are not limited to sma, rp - sma, mmcx, mcx, fme, and tnc.
sp e - 15 - 8 - 004 /c /jc page 5 of 8 4. installation disclaimer: installation of this device requires knowledge of basic electrical and experience with installing electronic devices. we recommend seeking a professional installer if you are not accustomed to installing electronics or high tech devices. instal lation of this device is at your own risk. taoglas assumes no responsibility for the installation or improper operation of this device. 4 .1 required items 1. ac/dc power adapter , +8v to +36v output voltage, >6 watts 2. cellular antenna 3. coaxial cab le with sma(m) connector and proper connector required for connecting to cellular device. 4. your cellular device 4 .2 instructions 1. connect antenna to sma connector labeled "antenna". 2. connect coaxial cable to sma connector labeled "device". 3. connect other end of coaxial cable to your cellular device. 4. power your device and observe the led indicators.
sp e - 15 - 8 - 004 /c /jc page 6 of 8 5. led diagnostics once the boost er is properly installed and power is applied, both leds will turn on followed by the green led flashing. the green led will flash while the boost er increases its gain to the optimum level. the red led may also flash during this stage while the gai n is pr operly set on the boost er. when power control is established, the green led will remain constantly on. you may see the green and red leds flash back and forth; this is normal. in areas where the cellular network is adequate, the boost er will maintain a max imum power level acceptable for normal operation and prevent overloading the wireless device, as well as keeping rf signal levels at a minimum for a healthy environment. if the red led is constantly on and the green led is off, the boost er has detected a f ault. the boost er will shut down automatically and restart. if the fault persists, reposition the antenna until normal operation is achieved. once normal operation is established, you may permanently mount the antennas in the locations you chose in prior s teps. diagnostic led definitions 1. solid green and red - led test, the unit is initializing 2. solid green - normal operation 3. flashing green - normal operation, increasing gain setting 4. solid green and flashing red - normal operation, decrea sing gain setting 5. solid red and no green - fault detected
sp e - 15 - 8 - 004 /c /jc page 7 of 8 6. drawing
sp e - 15 - 8 - 004 /c /jc page 8 of 8 fcc id: xs7 - wre2710 ic id: 8918a - wre2710 this device complies with part 15 of the fcc rules. operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. the term ic: before the radio certification number only signifies that industry of canada technical specific ations were met. the manufacturer's rated output power of this equipment is for single carrier operation. for situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 db, especially where the output signal is re - radi ated and can cause interference to adjacent band users. this power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. la puissance de sortie nominale indique par le fabricant pour cet appare il concerne son fonctionnement avec porteuse unique. pour des appareils avec porteuses multiples, on doit rduire la valeur nominale de 3,5 db, surtout si le signal de sortie est retransmis et qu'il peut causer du brouillage aux utilisateurs de bandes adja centes. une telle rduction doit porter sur la puissance d'entre ou sur le gain, et ne doit pas se faire au moyen d'un attnuateur raccord la sortie du dispositif. fc c regulatory guidance: the taoglas csb .01.a.001 operates under the rules and regulations as provided by the federal communications commission (fcc). for more information on these rules and regulations, please contact the fcc directly at (888) - 225 - 5322.


▲Up To Search▲   

 
Price & Availability of CSB01A001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X